NIAOT OpenIR
Calibration approach of non-modulated pyramid wavefront sensors for improving the dynamic range
Bai H(白华)
2024-10-10
Source PublicationApplied Optics
Volume63Issue:29Pages:7767-7778
Abstract

The pyramid wavefront sensor(PWFS)can provide high sensitivity in demanding adaptive optics applications. However,its exquisite sensitivity has a limited dynamic range,which relies on the use of beam modulation to improve the dynamic range of the PWFS—despite this task being achieved by moving optical components in the PWFS,increasing the complexity of the system.An attractive idea to simplify the optical and mechanical design of a PWFS is to work without any dynamic modulation.

This paper proposes a new method,to the best of our knowledge,called the pyramid wavefront sensor with truncated axicon(TA-PWFS),which is used in the non-modulated PWFS in the closed-loop adaptive optics system with high sensitivity and high dynamic range without the need for cumbersome modulation.

The new approach uses a diffractive element placed at a conjugated Fourier plane of the pyramid prism to shape part of the incident light in a ring pattern around the pyramid pin. The radius of the circular-shaped image is identical to that of the modulation radius in the sinusoidal modulation, offering a high dynamic range,while the remaining portion of the light continues un-diffracted,producing high sensitivity through a spot on the pyramid pin.

Simulation results with different kinds of aberrations containing large global tilts reveal that the use of the TA-PWFS has a noticeable improvement in the aberration estimation performance.

With a highly simplified structure,elements without mechanical modulation,and aberration recon struction without precorrection of global tilt,the TA-PWFS could present an innovative method for the design of non-modulated pyramid wavefront sensors that can better suit the higher requirements of adaptive optics applications.

Subject Area天文技术与方法
Document Type期刊论文
Identifierhttp://ir.niaot.ac.cn/handle/114a32/2262
Collection中国科学院南京天文光学技术研究所知识成果
期刊论文
Affiliation南京天文光学技术研究所
Recommended Citation
GB/T 7714
Bai H. Calibration approach of non-modulated pyramid wavefront sensors for improving the dynamic range[J]. Applied Optics,2024,63(29):7767-7778.
APA Bai H.(2024).Calibration approach of non-modulated pyramid wavefront sensors for improving the dynamic range.Applied Optics,63(29),7767-7778.
MLA Bai H."Calibration approach of non-modulated pyramid wavefront sensors for improving the dynamic range".Applied Optics 63.29(2024):7767-7778.
Files in This Item: Download All
File Name/Size DocType Version Access License
Calibration approach(8745KB)期刊论文出版稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Bai H(白华)]'s Articles
Baidu academic
Similar articles in Baidu academic
[Bai H(白华)]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Bai H(白华)]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Calibration approach of non-modulated pyramid wavefront sensors for improving the dynamic range.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.