Active support scheme may decide the deformation of the optical surface figure of
the primary mirror. Two main active axial support schemes are often adopted to the thin meniscus primary mirror, one scheme is that the axial supports normal to the mirror bottom surface, and the other is that the active forces parallel to the optical axis. In order to compare the performance of the two support schemes, 1-m thin meniscus primary mirror is conducted. Finite element analysis (FEA) is employed to analyze the optical surface figures of the primary mirror, and optimizations are carried out by using ANSYS for each support scheme to obtain the locations and active forces.

The axial support force sensitivities are calculated for the two support schemes in a case that a single axial support has a force error of 0.5 N. The correction ability of the active support system for both of the support schemes are analyzed when an arbitrary axial support is failure. Several low order Zernike modes are modeled with MATLAB procedure, and active optics corrections are applied to these modes for the two active supports. The extra mirror surface error due to thermal deformation is also corrected with the two support schemes.
关键词Overall Mechanics Design (Support Structures And Materials, Vibration Analysis Etc) Instrument Optimisation Optics Mirror Quality Factor
学科领域天文技术与方法
WOS记录号WOS:000316990700055
引用统计
文献类型期刊论文
条目标识符http://ir.niaot.ac.cn/handle/114a32/729
专题期刊论文
推荐引用方式
GB/T 7714
D.S. Niu,G.M. Wang,B.Z. Gu,et al. Performance comparison between two axial active support schemes for 1-m thin meniscus primary mirror[J]. Journal of Instrumentation,2013,8(3):1-9.
APA D.S. Niu,G.M. Wang,B.Z. Gu,&Y. Yea.(2013).Performance comparison between two axial active support schemes for 1-m thin meniscus primary mirror.Journal of Instrumentation,8(3),1-9.
MLA D.S. Niu,et al."Performance comparison between two axial active support schemes for 1-m thin meniscus primary mirror".Journal of Instrumentation 8.3(2013):1-9.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Performance comparis(580KB) 开放获取CC BY-NC-ND浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[D.S. Niu]的文章
[G.M. Wang]的文章
[B.Z. Gu]的文章
百度学术
百度学术中相似的文章
[D.S. Niu]的文章
[G.M. Wang]的文章
[B.Z. Gu]的文章
必应学术
必应学术中相似的文章
[D.S. Niu]的文章
[G.M. Wang]的文章
[B.Z. Gu]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Performance comparison between two axial active support schemes for 1-m thin meniscus primary mirror .pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。